Capacity: 0.1t/h-50t/h; 100kw-35000kw; 10hp-3000hp
Working Pressure: 0.1Mpa-3.8Mpa; 1bar-38bar
Aavailable fuel: Natural gas, lpg, oil, diesel, heavy oil, exhaust gas, dual fuel
Vacuum hot water boiler adopts principle of water-fire tube boiler, SU304S stainless steel heat exchanger, high heat transfer efficiency of flue gas, compact structure, high efficiency and energy saving, ultra low NOx emission and small volume.
The vacuum boiler operates under negative pressure and has multiple protection functions, It is safe and reliable and never explodes. It has exquisite appearance, convenient installation, convenient maintenance and no need for supervision.
1. Safety:
There is no danger of expansion, explosion or rupture during negative pressure operation;
2. Long service life:
The heat medium water heat exchange system is used, there is no scaling and corrosion phenomenon, the boiler maintenance and after-sales problems are reduced, and the service life of the boiler is greatly increased;
3. Exemption from inspection products:
Negative pressure operation products, the relevant state departments are exempt from inspection and supervision;
4. Small size:
Can be placed in the basement and roof, more conducive to the boiler room configuration, modular parallel connection;
5. Environmental protection:
The measured minimum emission of NOX is 20mg/m3, in line with the most stringent environmental protection standards;
6. Energy saving:
The measured air consumption of the 0.7MW hot water boiler in one hour is <60m3, which is far lower than the industry data;
Main accessories of Gas/Oil fired boiler:
1.Our Boiler design adopt heat transfer, flow resistance technology ,heat exchanger use high efficiency heat transfer material,it enlarged the heat-exchange unit heating surface and improved the heat transfer efficiency.
2.Safety and steady.Vacuum hot water boiler working under negative pressure
3.The medium hot water won't reudce or increase,won't go in or go out. The medium hot water is without oxygen corrosion,won't scale,it will prolong life-span 2-3 times.
4.Adopt patent technology.Boiler can supply different heat accoring to thermal requirements when outdoor temperature change.It willsupply comfortable temperature and at same time save energy ..
Model |
|
|
|
ZWNS | ZWNS | ZWNS | ZWNS | ZWNS | ||
---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
0.7 | 1.05 | 1.4 |
|
2.1 | ||
Heat output | MW |
|
|
|
0.7 | 1.05 | 1.4 |
|
2.1 | |
×104 |
|
|
|
60 | 90 | 120 |
|
180 | ||
Kcal/h |
|
|
|
|
|
|
|
|
||
Meterial of heat exchanger |
stainless steel tube | |||||||||
Working pressure of heat exchanger |
1.0 Mpa | |||||||||
A-model heat exchanger | Application |
|
Apply to heating | |||||||
Inlet/Outlet water temperature |
°C |
55/60(=5°C)
|
||||||||
Hot water flow | m³/H | 40 | 60 | 80 | 120 | 180 | 240 | 300 | 360 | |
B-model heat exchanger | Application |
|
Apply to heating, hot water circulation etc.
|
|||||||
Inlet/Outlet water temperature |
°C |
50/60(=10°C)
|
||||||||
Hot water flow | m³/H | 20 | 30 | 40 | 60 | 90 | 120 | 150 | 180 | |
C-model heat exchanger | Application |
|
Apply to sanitary hot water,radiator heating circulation etc. |
|||||||
Inlet/Outlet water temperature |
°C |
40/60 or 60/80(=20°C) |
||||||||
Hot water flow | m³/H | 10 | 15 | 20 | 30 | 45 | 60 | 75 | 90 | |
Hot water output per hour(10-60°C) |
T/H | 4 | 6 | 8 | 12 | 18 | 24 | 30 | 36 | |
Cumbustion regulatin mode |
|
|
Full automatic single/double phase fire regulation | |||||||
Fuel |
|
|
60#heavy oil/diesel/natural gas/LPG/Coal gas | |||||||
Fuel consumption | 60#heavy oil | Kg/h | 22.8 | 34.2 | 45.6 | 68.4 | 102.7 | 136.9 | 171.1 | 205.3 |
Diesel | Kg/h | 22 | 32.9 | 43.8 | 65.8 | 98.7 | 131.5 | 164.4 | 197.3 | |
Natural gas | Nm³/h | 26.5 | 39.7 | 52.9 | 79.3 | 119 | 158.6 | 198.3 | 237.9 | |
LPG | Nm³/h | 8.5 | 13.2 | 17.6 | 26.3 | 39.5 | 52.7 | 65.8 | 79 | |
Coal gas | Nm³/h | 56.2 | 84.3 | 112.4 | 168.5 | 252.8 | 337.1 | 421.3 | 505.6 | |
External dimension | Length | mm | 2440 | 3008 | 3360 | 3440 | 3536 | 4130 | 4408 | 4726 |
Width | mm | 970 | 1140 | 1300 | 1440 | 1550 | 1550 | 1830 | 1830 | |
Height | mm | 1490 | 1957 | 2200 | 2450 | 2500 | 2500 | 2968 | 2994 | |
Weight |
|
T | 1.3 | 2.1 | 2.45 | 3.4 | 4.4 | 4.5 | 6.3 | 6.9 |