Your position:
Home > Products > Oil Gas Boiler
    • medical waste incinerator, dead animal incinerator
    • medical waste incinerator, dead animal incinerator
    • medical waste incinerator, dead animal incinerator
    • medical waste incinerator, dead animal incinerator

    Incinerator

    Model:YDF series incinerator
    Burning ability:20kg-750kg per time (daily incineration3-6 times)
    Voltage:380V/220V
    Used in:Hospitals, animal farms, slaughterhouses, enterprises...
    Brief Intro:YDF series multi-functions incinerator, its a ideal waste treatment device, strictly obey to environment emission, mostly used in hospital, farms
    Get price Send Message
    captcha
    Introduction Parameters Incinerator Showing Product Case
    Introduction

    Incinerator 20kg-500kg per time, daily incineration3-6 times

    YDF series multi-functions incinerator, its a ideal waste treatment device, strictly obey to environment emission, mostly used in hospital, farms

     incinerators

    Incinerator First Consumbustion Chamber Volume As Following:

    hospital incinerator,medical incinerator,medical waste incinerator

    YDF Series Pyrolysis Furnaces Incinerator for waste incineration are designed according to the CE directive and regulation, suitable for the incineration of clinical waste in healthcare facilities, clean and hassle-free disposal and safe destruction of:

    medical waste incinerator,incinerator work principle

    1.Medical waste: syringes, neddles, gloves, straps, gauze, blood vessels, organs and other infectious waste.

    2. Industrial waste (polymer waste): Plastic PE, PU, rubber (tire), Styrofoam, PET bottle, fiber, foam, cloth, bags, resin, acrylic, leather, Wood flour, urea powder, melon cloth, tapes, paints, polymers and so on.

    3. General garbage: cardboard, paper scraps, sawdust, leaves and so on.

    4. Special waste: waste oil, waste solvents, oil sludge, ash dust, iron paint, mold filter residue and so on.

    5. Pet Animal carcass cremation.

    Hospital Medical Waste Clinical Waste Incinerator,medical incinerator

     Characteristics of Incinerator 

    1. Smokeless and Odorless, No Blank Smoke

    High-temperature pyrolysis gasification technology+mixed incineration+burnout treatment.

    Single/double/multi-stage flue gas treatment.

    Enclosed burning, avoid secondary pollution.

    2. High Temperature Pyrolysis Process

    Double chamber for incineration.

    The chamber temperature up to 1300°C, retention 2 seconds.

    3. Low Consump Cost

    With first-class Itlay Baltur burner, ensure good qualtiy.

    Primary combustion chamber automatically starts and stops, effectively utilizing high-temperature flue gas, save fuel.

    4. Safe 100%, Good Quality

    Use ceramic fiber sealing tape rather than asbestos material. And high-strength refractory materials.

    Security protection: auto ignition, auto control and temperature monitoring, automatic power cut off.

    5. Easy to Install and Operate

    Pre-assembled and well-debugged in our factory. 

    Simple to install the incinerator by Installation Steps.

    incinerator structure,medical waste incinerators, pets cremation

    Advantages & Features

    1. Waste Incinerator is a kind of waste treatment equipment,which is an ideal waste treatment equipment for various hospitals, animal breeding farms, slaughterhouses, large commercial organizations, enterprises and institutions.

    2. lt can reduce the solid mass of the original waste by 80-85% and the volume reduced by 95-96%.

    3. The waste is treated innocuously, completely killing the virus.

    4. There will be no smoke, no smell and no pollution after burning of waste.

    Customers Feedback Pictures

    incinerators

    Parameters
    Models YDF-20 YDF-30 YDF-50 YDF-100 YDF-150 YDF-300 YDF-500
    Processing Capacity (kg/batch) 10-20 20-30 30-50 50-100 100-150 200-300 300-500
    Working Hours Per Batch Cycle* (min) 90-120
    Primary Chamber Volume (m3) 0.2 0.38 0.5 1 1.5 2.4 3.5
    Waste Feeding Gate Size (mm) 380 x 480 480 x 600 620 x 800 700 x 900 760 x 960 900 x 1100 1080 x 1280
    Temperature (℃) Primary Chamber 900
    Second Chamber 1300
    Smoke Residence Time (s) > 2 sec in second chamber
    Applicable Waste Type Hazard Medical Waste/Consumables, Plastic, Paper, Domestic Waste, Animal Corpse, Electronic Component
    Primary Burner - Baltur Italy BTL-6, 0.11kw BTL-6, 0.11kw BTL-10, 0.11kw BTL-10, 0.11kw BTL-10, 0.11kw BTL-10, 0.11kw BTL-14, 0.18kw
    Second Burner - Baltur Italy BTL-10, 0.11kw BTL-14, 0.18kw BTL-14, 0.18kw BTL-20, 0.18kw BTL-20, 0.18kw BTL-26, 0.25kw BTL-35, 0.37kw
    Total Diesel** Consumption (litre/h) 11-18 11-18 14-23 16-35 16-35 20-40 38-57
    FD Fan Power (kw) 0.37 0.37 0.55 0.75 0.75 0.75 0.75+0.75
    Applicable Voltage 380V 3Phase / 220V 1Phase
    Outer Dimensions (m) 1.6 x 1.3 x 2.65 1.45 x 0.9 x 2.6 1.8 x 1.2 x 3 1.86 x 1.4 x 3.2 2.1 x 1.5 x 3.5 2.25 x 1.6 x 3.8 3.0 x 2.0 x 4.8
    Chimney Dimensions (mm) φ280 x 6000 φ280 x 6000 φ300 x 9000 φ330 x 9000 φ380 x 9000 φ400 x 9000 φ460 x 9000
    Weight (kg) 2000 3000 5000 6800 8000 9600 15000
    Manufacturing Standard GB 18484-2020 (equals to EPA or EU standards)
    Incinerator Showing

     Yuanda YDF Incinerators Equipment 

    gas oil burner incinerator,gas fired incinerator,oil fired incinerator

     Incinerator with filtration system 

    china incinerator,smokeless waste incinerator,garbage incinerator furnace
    Product case

    InquiryPlease feel free to submit your inquiry information to us.

    * Your Email :
    Your Tel :
    Your Name :
    * Your Inquiry :